Guangzhou Yoondon Lighting Electrical Co., Ltd.
Main products:Energy-saving lamps,led light,Dimmer switches,transformer
Products
Contact Us
  • Contact Person : Mr. yuan George
  • Company Name : Guangzhou Yoondon Lighting Electrical Co., Ltd.
  • Tel : 86-020-28934226
  • Fax : 86-020-84610677
  • Address : Guangdong,Guangzhou,4049.No.46-56,Shia Qiao Guang Chang Xi Lu,Pan Yu District
  • Country/Region : China
  • Zip : 510400

T5 T8 LED tube Microwave motion dimmable sensor dimming Used in the parking lot

T5 T8 LED tube Microwave motion dimmable sensor dimming Used in the parking lot
Product Detailed
human body light motion sensor switch 1.with dimming function 2.certificate:CE best price & fast delivery time

Range of application&Functions and Features

 Microwave motion dimmable sensor is the latest research and development of microwave intelligent lighting control . Its based Doppler principle and RADAR technology, adopting flat plane antenna & high 

performance micro-chip. 

It is easy to install, provide high probability of detection, low nuisance alarms and resistance to rain, fog, 

wind, dust, falling snow and temperature extremes.

 

It can be applied to control various constant current, constant voltage LED lamps, further achieve high 

performance green energy-saving.

 

It can be widely used in public places such as corridor, sidewalk,parking garage, warehouse and office 

space etc.

 

  Specification

1

Voltage

30V DC- 100V DC 

2

Rated power

60W (Max.)

3

Standby power

<0.9 W, Not include power supply

4

Detection area

10%/30%/50%/80%/100%, adjustable

5

Hold time

5s/15s/3min/5min/10min, adjustable

6

Standby Dimming level

0%/5%/10%/30%/50%, adjustable

7

Microwave frequency

5.8GHz +/-75MHz

8

Microwave power

<2mW

9

Detection range

1-10 meters

10

Detection angle

180°

11

Mounting height

Max 8m

12

Operating temperature

-35°C~+70°C

13

Working light

2-2000lux, can be customized

Wiring

Settings

 Troubleshooting

Malfunction 

Cause

Remedy

The Load does not work

Wrong light control setting selected 

Adjust setting

The load work always

Continuous movement in the detection zone

Check zone setting

The load work without any identifiable movement

Sensor not mounted for detecting movement reliably

Reinforcement            install accessories

Movement occurred, but not been identified by the 

sensor (movement behind wall, movement of a small object in immediate lamp vicinity etc.)

Check the induction space settings

The load will not work despite movement

The detection zone you have set is too small

Check the induction settings

Packing

T5 T8 LED tube Microwave motion dimmable sensor dimming Used in the parking lot



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.